A 4 i of 1000 dme 100 cm2. ?Decontamination?efforts have reduced the remainder of the area to normal contamination levels. 6 . Stack Ef?uent Activity Radioactivity routed to the stack from thegaseous storage tanks passes through absolute filters and is then diluted with 25,000 of outside air. Ex- haust from the high bay area is not vented to the stack but rather to a separate outlet located on top of the high bay area. The high bay exhaust is passed through CWS filters only when potentially hazardous operations are in progress within the reactor building, e. g. during reactor operation or fuel handling. .The original design of the gaseous waste handling system incorporated radiation? level?actuated by-pass valves in the line leading from each source of gaseous activity to the storage tanks. In this way, automatically and depending on the activity level, the gas would be vented either to the stack or to the storage tanks. This system was later modified, because of malfunction, and a manually oper- ated bypass was placed in the reactor control room. Prior to run 14, there had been no indication that activity concentrations in the stack ef?uent had exceeded'allo?able values. On several occasions, the stack monitor had indicated the presence of high activity levels, but the cause could always be traced to either instrument malfunction or the fact that the in- strument was responding to direct radiation (usually resultant from radiation beams existing at the same time in the high bay area). Two instances in which the stack monitor readings indicated activity con- centrations in excess of allowable values were noted during run 14. The first of these occurred on July 12 at 1700, at which time the stack activity rose sharply to a value of 1.5 This instance of apparent high activity levels occurred simultaneously with the high radiation levels which were detect- ed above core channel number 7 and, as a result, the stack monitor was re? sponding to this direct radiation. The activity level returned to normal by 2200 on the same day. The. second instance Jul if; 31%; this, time the sharply to 7 10-5 Ec/cm . The activitv level Mm continued intermittently high until about 1100 alluly No explanation can be offered for this second occurrence unless it is assumed that the storage tank I u-?I bypass switch_l_1_?d inadvertently b?enplaced in the bypass osition. If this were NFC-24