DEPARTMENT OF TRANSPORTATION INSPECTION REPORT FEDERAL RAILROAD ADMINISTRATION (FRA) Inspector's Name Inspector's Signature OMB Approval No.: 2130-0509 Inspector's ID No. HOLM, STEVEN L. 00417 Railroad/Company Name & Address R/C UNION PACIFIC RR CO. R 1000 E 1ST ST. THE DALLES OR 97355 Date Report No. 28 yy mm 2016 04 Division RR/Co. Representative (Receipt Acknowledged) SYSTEM Name PETE VALLEJO RR/Co. Code Subdivision Title TRACK INSPECTOR UP PORTLAND Email dd 27 Signature From: City THE DALLES State County Codes 2060 Destination City & County OR 41 City WASCO C065 County Mile Post: From 0084.68 To CASCADE LOCKS HOOD RIVER Inspection Point CORTEX TRACK INSPECTION 0035.30 Activity Code: MTH MTW RMM RWP TOM Units: 48 1 1 1 14 Sub Units: 0 0 0 4 0 Item 1 Initials/Milepost 0084.59 Equipment/Track # MAIN 1 Type/Kind 49 CFR/ USC T 213 From Latitude Codes Defect Subrule Speed 0133 A12 40 0300 From Longitude C027 To Latitude To Longitude Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 3 N N 1 TOM Description LOOSE FROG BOLTS. ( CHERRY GROWERS, 1 MIDDLE FROG, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Hazard Class Latitude: Yes No Required Optional Written Notification to Item 2 Initials/Milepost 0084.59 Longitude: Railroad Action Code FRA of Remedial Action is: Equipment/Track # MAIN 1 Type/Kind 49 CFR/ USC T UN/NA ID 213 Defect Subrule 0135 A1 Date(mm/dd/yyyy): Speed 40 Comments on back? Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 3 N N 1 TOM Description STOCK RAIL NOT SECURELY SEATED IN SWITCH PLATES. ( LEFT HAND SIDE AT HEEL OF SWITCH, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Yes No Required Optional Written Notification to FRA of Remedial Action is: Hazard Class Latitude: Railroad Action Code Source Code File Number D UN/NA ID Longitude: Date(mm/dd/yyyy): Comments on back? ID's of Accompanying Inspector(s) R8CORTEX Page FORM FRA F 6180.96 (Revised 07/14) *SNFR-Special Notice for Repairs FRA COPY 1 of 9 **RCL-Remote Control Locomotive ***# of Occ.-Number of Occurrences DEPARTMENT OF TRANSPORTATION INSPECTION REPORT FEDERAL RAILROAD ADMINISTRATION (FRA) Inspector's ID No. Report No. 00417 Item 3 28 Initials/Milepost 0083.82 OMB Approval No.: (Continuation) 2130-0509 Report Date 4/27/2016 Equipment/Track # MAIN 1 Type/Kind 49 CFR/ USC T 213 Defect Subrule 0133 A9 Speed 40 Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 3 N N 1 TOM Description LOOSE ADJUSTABLE RAIL BRACES. ( CHERRY GROWERS 2, RIGHT HAND SIDE GAGE PLATE, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Hazard Class Latitude: Yes No Required Optional Written Notification to Item 4 Initials/Milepost 0083.82 Longitude: Railroad Action Code FRA of Remedial Action is: Equipment/Track # MAIN 1 Type/Kind 49 CFR/ USC T UN/NA ID 213 Defect Subrule 0135 A1 Date(mm/dd/yyyy): Speed 40 Comments on back? Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 3 N N 1 TOM Description STOCK RAIL NOT SECURELY SEATED IN SWITCH PLATES. ( RIGHT HAND SIDE AT HEEL, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Hazard Class Latitude: Yes No Required Optional Written Notification to Item 5 Initials/Milepost 0083.82 Longitude: Railroad Action Code FRA of Remedial Action is: Equipment/Track # MAIN 1 Type/Kind 49 CFR/ USC T UN/NA ID 213 Date(mm/dd/yyyy): Defect Subrule Speed 0133 A12 40 Comments on back? Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 3 N N 1 TOM Description LOOSE FROG BOLTS. ( 1 IN HEEL, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Hazard Class Latitude: Yes No Required Optional Written Notification to Item 6 Initials/Milepost 0083.50 Longitude: Railroad Action Code FRA of Remedial Action is: Equipment/Track # MAIN 1 Type/Kind 49 CFR/ USC M UN/NA ID 213 Defect Subrule 0037 B1 Date(mm/dd/yyyy): Speed 40 Comments on back? Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 3 N N 1 MTH Description VEGETATION OBSTRUCTS VISIBILITY OF RAILROAD SIGN. ( NORTH SIDE OF TRACK, BUSHES IN FRONT OF WB CROSSING (X) SIGN ) Seal Applied Seal Removed Violation Recommended Yes No Required Optional Written Notification to FRA of Remedial Action is: Hazard Class Latitude: Railroad Action Code Source Code File Number D UN/NA ID Longitude: Date(mm/dd/yyyy): Comments on back? ID's of Accompanying Inspector(s) R8CORTEX Page FORM FRA F 6180.96 (Revised 07/14) *SNFR-Special Notice for Repairs FRA COPY 2 of 9 **RCL-Remote Control Locomotive ***# of Occ.-Number of Occurrences DEPARTMENT OF TRANSPORTATION INSPECTION REPORT FEDERAL RAILROAD ADMINISTRATION (FRA) Inspector's ID No. Report No. 00417 Item 7 28 Initials/Milepost 0077.33 OMB Approval No.: (Continuation) 2130-0509 Report Date 4/27/2016 Equipment/Track # SIMN Type/Kind 49 CFR/ USC T 213 Defect Subrule 0135 B1 Speed 60 Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 TOM Description IMPROPER FIT BETWEEN SWITCH POINT AND STOCK RAIL. ( RIGHT HAND SIDE POINT GAP, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Hazard Class Latitude: Yes No Required Optional Written Notification to Item 8 Initials/Milepost 0070.79 Longitude: Railroad Action Code FRA of Remedial Action is: Equipment/Track # SIMN Type/Kind 49 CFR/ USC T UN/NA ID 213 Date(mm/dd/yyyy): Defect Subrule Speed 0133 A12 60 Comments on back? Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 TOM Description LOOSE FROG BOLTS. ( CPS 071, CARRIAGE BOLTS, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Hazard Class Latitude: Yes No Required Optional Written Notification to Item 9 Initials/Milepost 0069.44 Longitude: Railroad Action Code FRA of Remedial Action is: Equipment/Track # SIMN Type/Kind 49 CFR/ USC T UN/NA ID 213 Date(mm/dd/yyyy): Defect Subrule Speed 0133 A13 60 Comments on back? Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 TOM Description LOOSE GUARD RAIL BOLTS. ( CPS 069, CARRIAGE BOLTS, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Hazard Class Latitude: Yes No Required Optional Written Notification to Item 10 Initials/Milepost 0064.92 Longitude: Railroad Action Code FRA of Remedial Action is: Equipment/Track # SIMN Type/Kind 49 CFR/ USC M UN/NA ID 213 Defect Subrule 0037 E3 Date(mm/dd/yyyy): Speed 60 Comments on back? Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 MTH Description VEGETATION BRUSHING SIDES OF ROLLING STOCK ( TREE ON SOUTH SIDE OF TRACK ) Seal Applied Seal Removed Violation Recommended Yes No Required Optional Written Notification to FRA of Remedial Action is: Hazard Class Latitude: Railroad Action Code Source Code File Number D UN/NA ID Longitude: Date(mm/dd/yyyy): Comments on back? ID's of Accompanying Inspector(s) R8CORTEX Page FORM FRA F 6180.96 (Revised 07/14) *SNFR-Special Notice for Repairs FRA COPY 3 of 9 **RCL-Remote Control Locomotive ***# of Occ.-Number of Occurrences DEPARTMENT OF TRANSPORTATION INSPECTION REPORT FEDERAL RAILROAD ADMINISTRATION (FRA) Inspector's ID No. Report No. 00417 Item 11 28 Initials/Milepost 0063.08 OMB Approval No.: (Continuation) 2130-0509 Report Date 4/27/2016 Equipment/Track # SIMN Type/Kind 49 CFR/ USC T 213 Defect Subrule 0133 A9 Speed 60 Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 TOM Description LOOSE ADJUSTABLE RAIL BRACES. ( E. HOOD RIVER, LEFT HAND SIDE # 5 BRACE, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Hazard Class Latitude: Yes No Required Optional Written Notification to Item 12 Initials/Milepost 0063.08 Longitude: Railroad Action Code FRA of Remedial Action is: Equipment/Track # SIMN Type/Kind 49 CFR/ USC T UN/NA ID 213 Date(mm/dd/yyyy): Defect Subrule Speed 0133 A12 60 Comments on back? Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 TOM Description LOOSE FROG BOLTS. ( CARRIAGE BOLTS, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Hazard Class Latitude: Yes No Required Optional Written Notification to Item 13 Initials/Milepost 0063.08 Longitude: Railroad Action Code FRA of Remedial Action is: Equipment/Track # SIMN Type/Kind 49 CFR/ USC T UN/NA ID 213 Defect Subrule 0139 E Date(mm/dd/yyyy): Speed 60 Comments on back? Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 TOM Description EXCESSIVE CLEARANCE BETWEEN HOLD-DOWN HOUSING AND HORN. ( MEASURES 5/16 OF INCH, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Hazard Class Latitude: Yes No Required Optional Written Notification to Item 14 Initials/Milepost 0062.24 Longitude: Railroad Action Code FRA of Remedial Action is: Equipment/Track # SIMN Type/Kind 49 CFR/ USC T UN/NA ID 213 Defect Subrule 0133 A9 Date(mm/dd/yyyy): Speed 60 Comments on back? Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 TOM Description LOOSE ADJUSTABLE RAIL BRACES. ( W. HOOD RIVER, LEFT HAND SIDE #3 BRACE, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Yes No Required Optional Written Notification to FRA of Remedial Action is: Hazard Class Latitude: Railroad Action Code Source Code File Number D UN/NA ID Longitude: Date(mm/dd/yyyy): Comments on back? ID's of Accompanying Inspector(s) R8CORTEX Page FORM FRA F 6180.96 (Revised 07/14) *SNFR-Special Notice for Repairs FRA COPY 4 of 9 **RCL-Remote Control Locomotive ***# of Occ.-Number of Occurrences DEPARTMENT OF TRANSPORTATION INSPECTION REPORT FEDERAL RAILROAD ADMINISTRATION (FRA) Inspector's ID No. Report No. 00417 Item 15 28 Initials/Milepost 0062.24 OMB Approval No.: (Continuation) 2130-0509 Report Date 4/27/2016 Equipment/Track # SIMN Type/Kind 49 CFR/ USC T 213 Defect Subrule Speed 0133 A15 60 Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 TOM Description TURNOUT FASTENINGS NOT INTACT. ( LEFT HAND GUARD RAIL, MARKED WITH SURVEYOR TAPE, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Hazard Class Latitude: Yes No Required Optional Written Notification to Item 16 Initials/Milepost 0059.40 Longitude: Railroad Action Code FRA of Remedial Action is: Equipment/Track # SIMN Type/Kind 49 CFR/ USC T UN/NA ID 213 Defect Subrule 0133 A9 Date(mm/dd/yyyy): Speed 60 Comments on back? Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 TOM Description LOOSE ADJUSTABLE RAIL BRACES. ( CPS 059, LEFT HAND SIDE #3 BRACE, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Hazard Class Latitude: Yes No Required Optional Written Notification to Item 17 Initials/Milepost 0059.40 Longitude: Railroad Action Code FRA of Remedial Action is: Equipment/Track # SIMN Type/Kind 49 CFR/ USC T UN/NA ID 213 Defect Subrule 0133 A6 Date(mm/dd/yyyy): Speed 60 Comments on back? Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 TOM Description LOOSE SWITCH ROD BOLTS. ( #2 SWITCH ROD, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Hazard Class Latitude: Yes No Required Optional Written Notification to Item 18 Initials/Milepost 0059.40 Longitude: Railroad Action Code FRA of Remedial Action is: Equipment/Track # SIMN Type/Kind 49 CFR/ USC T UN/NA ID 213 Date(mm/dd/yyyy): Defect Subrule Speed 0133 A15 60 Comments on back? Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 TOM Description TURNOUT FASTENINGS NOT INTACT. ( HORN BOLT LOOSE, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Yes No Required Optional Written Notification to FRA of Remedial Action is: Hazard Class Latitude: Railroad Action Code Source Code File Number D UN/NA ID Longitude: Date(mm/dd/yyyy): Comments on back? ID's of Accompanying Inspector(s) R8CORTEX Page FORM FRA F 6180.96 (Revised 07/14) *SNFR-Special Notice for Repairs FRA COPY 5 of 9 **RCL-Remote Control Locomotive ***# of Occ.-Number of Occurrences DEPARTMENT OF TRANSPORTATION INSPECTION REPORT FEDERAL RAILROAD ADMINISTRATION (FRA) Inspector's ID No. Report No. 00417 Item 19 28 Initials/Milepost 0057.35 OMB Approval No.: (Continuation) 2130-0509 Report Date 4/27/2016 Equipment/Track # SIMN Type/Kind 49 CFR/ USC T 213 Defect Subrule 0133 A9 Speed 60 Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 TOM Description LOOSE ADJUSTABLE RAIL BRACES. ( CPS 057, RIGHT HAND SIDE #7 BRACE, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Hazard Class Latitude: Yes No Required Optional Written Notification to Item 20 Initials/Milepost 0057.35 Longitude: Railroad Action Code FRA of Remedial Action is: Equipment/Track # SIMN Type/Kind 49 CFR/ USC T UN/NA ID 213 Defect Subrule 0133 A7 Date(mm/dd/yyyy): Speed 60 Comments on back? Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 TOM Description MISSING COTTER PINS. ( HORN BOLTS, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Hazard Class Latitude: Yes No Required Optional Written Notification to Item 21 Initials/Milepost 0051.74 Longitude: Railroad Action Code FRA of Remedial Action is: Equipment/Track # SIMN Type/Kind 49 CFR/ USC T UN/NA ID 213 Defect Subrule 0133 A9 Date(mm/dd/yyyy): Speed 60 Comments on back? Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 TOM Description LOOSE ADJUSTABLE RAIL BRACES. ( CPS 052, RIGHT HAND SIDE #5 BRACE, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Hazard Class Latitude: Yes No Required Optional Written Notification to Item 22 Initials/Milepost 0051.74 Longitude: Railroad Action Code FRA of Remedial Action is: Equipment/Track # SIMN Type/Kind 49 CFR/ USC T UN/NA ID 213 Defect Subrule 0133 A7 Date(mm/dd/yyyy): Speed 60 Comments on back? Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 TOM Description MISSING COTTER PINS. ( LEFT HAND SWITCH ROD BOLT, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Yes No Required Optional Written Notification to FRA of Remedial Action is: Hazard Class Latitude: Railroad Action Code Source Code File Number D UN/NA ID Longitude: Date(mm/dd/yyyy): Comments on back? ID's of Accompanying Inspector(s) R8CORTEX Page FORM FRA F 6180.96 (Revised 07/14) *SNFR-Special Notice for Repairs FRA COPY 6 of 9 **RCL-Remote Control Locomotive ***# of Occ.-Number of Occurrences DEPARTMENT OF TRANSPORTATION INSPECTION REPORT FEDERAL RAILROAD ADMINISTRATION (FRA) Inspector's ID No. Report No. 00417 Item 23 28 Initials/Milepost 0051.74 OMB Approval No.: (Continuation) 2130-0509 Report Date 4/27/2016 Equipment/Track # SIMN Type/Kind 49 CFR/ USC T 213 Defect Subrule Speed 0133 A15 60 Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 TOM Description TURNOUT FASTENINGS NOT INTACT. ( HORN BOLT LOOSE, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Hazard Class Latitude: Yes No Required Optional Written Notification to Item 24 Initials/Milepost 0049.17 Longitude: Railroad Action Code FRA of Remedial Action is: Equipment/Track # SIMN Type/Kind 49 CFR/ USC T UN/NA ID 213 Date(mm/dd/yyyy): Defect Subrule Speed 0133 A12 60 Comments on back? Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 TOM Description LOOSE FROG BOLTS. ( CPS 050, CARRIAGE BOLTS, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Hazard Class Latitude: Yes No Required Optional Written Notification to Item 25 Initials/Milepost 0049.17 Longitude: Railroad Action Code FRA of Remedial Action is: Equipment/Track # SIMN Type/Kind 49 CFR/ USC T UN/NA ID 213 Defect Subrule 0133 A7 Date(mm/dd/yyyy): Speed 60 Comments on back? Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 TOM Description MISSING COTTER PINS. ( FROG CARRIAGE BOLTS, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Hazard Class Latitude: Yes No Required Optional Written Notification to Item 26 Initials/Milepost 0043.44 Longitude: Railroad Action Code FRA of Remedial Action is: Equipment/Track # SIMN Type/Kind 49 CFR/ USC T UN/NA ID 213 Defect Subrule 0133 A9 Date(mm/dd/yyyy): Speed 60 Comments on back? Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 TOM Description LOOSE ADJUSTABLE RAIL BRACES. ( CPS 043, RIGHT HAND SIDE GAGE PLATE, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Yes No Required Optional Written Notification to FRA of Remedial Action is: Hazard Class Latitude: Railroad Action Code Source Code File Number D UN/NA ID Longitude: Date(mm/dd/yyyy): Comments on back? ID's of Accompanying Inspector(s) R8CORTEX Page FORM FRA F 6180.96 (Revised 07/14) *SNFR-Special Notice for Repairs FRA COPY 7 of 9 **RCL-Remote Control Locomotive ***# of Occ.-Number of Occurrences DEPARTMENT OF TRANSPORTATION INSPECTION REPORT FEDERAL RAILROAD ADMINISTRATION (FRA) Inspector's ID No. Report No. 00417 Item 27 28 Initials/Milepost 0043.44 OMB Approval No.: (Continuation) 2130-0509 Report Date 4/27/2016 Equipment/Track # SIMN Type/Kind 49 CFR/ USC T 213 Defect Subrule 0133 A7 Speed Class Train #/Site 60 SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 TOM Description MISSING COTTER PINS. ( RIGHT HAND SIDE CLIP BOLT, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Hazard Class Latitude: Yes No Required Optional Written Notification to Item 28 Initials/Milepost 0043.44 Longitude: Railroad Action Code FRA of Remedial Action is: Equipment/Track # SIMN Type/Kind 49 CFR/ USC T UN/NA ID 213 Defect Subrule 0133 A2 Date(mm/dd/yyyy): Speed 60 Comments on back? Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 TOM Description LOOSE CLIP BOLT ( LEFT HAND SIDE #3 ROD, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Hazard Class Latitude: Yes No Required Optional Written Notification to Item 29 Initials/Milepost 0042.04 Longitude: Railroad Action Code FRA of Remedial Action is: Equipment/Track # SIMN Type/Kind 49 CFR/ USC T UN/NA ID 213 Date(mm/dd/yyyy): Defect Subrule Speed 0133 A14 60 Comments on back? Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 TOM Description LOOSE GUARD RAIL CLAMPS ( CPS 041, 3 ON LEFT HAND GUARD RAIL, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Hazard Class Latitude: Yes No Required Optional Written Notification to Item 30 Initials/Milepost 0049.17 Longitude: Railroad Action Code FRA of Remedial Action is: Equipment/Track # SIMN Type/Kind 49 CFR/ USC T UN/NA ID 213 Defect Subrule 0127 A Date(mm/dd/yyyy): Speed 60 Comments on back? Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 4 N N 1 TOM Description FAILURE OF FASTENING COMPONENTS TO EFFECTIVELY MAINTAIN GAGE ( LAGS ALLOW LATERAL MOVEMENT, MARKED WITH SURVEYOR TAPE ) Seal Applied Seal Removed Violation Recommended Yes No Required Optional Written Notification to FRA of Remedial Action is: Hazard Class Latitude: Railroad Action Code Source Code File Number D UN/NA ID Longitude: Date(mm/dd/yyyy): Comments on back? ID's of Accompanying Inspector(s) R8CORTEX Page FORM FRA F 6180.96 (Revised 07/14) *SNFR-Special Notice for Repairs FRA COPY 8 of 9 **RCL-Remote Control Locomotive ***# of Occ.-Number of Occurrences DEPARTMENT OF TRANSPORTATION FEDERAL RAILROAD ADMINISTRATION (FRA) Inspector's ID No. Report No. 00417 Item 28 Initials/Milepost INSPECTION REPORT OMB Approval No.: (Continuation) 2130-0509 Report Date 4/27/2016 Equipment/Track # Type/Kind 49 CFR/ USC Defect Subrule Speed Class Train #/Site SNFR* RCL** # of Activity Occ.*** Code 31 N N 0 Description - [** Comment to Railroad/Company **] THIS INSPECTION ENCOMPASSED THE MAIN TRACK AND TURNOUTS FROM THE DALLES TO CASCADE LOCKS. I WAS ACCOMPANIED DURING THIS INSPECTION BY UNION PACIFIC RAILROAD REPRESENTATIVES, PETE VALLEJO, JOE JOHNSTON AND CRAIG MERRILL. Seal Applied Seal Removed Violation Recommended Yes No Required Optional Written Notification to FRA of Remedial Action is: Hazard Class Latitude: Railroad Action Code Source Code File Number D UN/NA ID Longitude: Date(mm/dd/yyyy): Comments on back? ID's of Accompanying Inspector(s) R8CORTEX Page FORM FRA F 6180.96 (Revised 07/14) *SNFR-Special Notice for Repairs FRA COPY 9 of 9 **RCL-Remote Control Locomotive ***# of Occ.-Number of Occurrences