9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054 Telephone: 856-231-9449 Email: customerservice@iatl.com CERTIFICATE OF ANALYSIS Client: Philadelphia Media Network  801 Market Street, Ste 300 Report Date: Report No.: Philadelphia      PA     19107 Project: Project No.: Client: PHI001 5/1/2018 562684 - TEM Dust  Wipe Toxic City: Cassidy  Rev #3, 5/2/2018  TEM WIPE SAMPLE ANALYSIS SUMMARY Lab No.:6501599 Client No.:1 Location: Room 302, Top Of Air Conditioning Unit   Area (cm²): 100 Density (s/mm²): 76.9 Concentration (s/cm²): 370000 Asbestos Type(s): Tremolite   Lab No.:6501600 Client No.:2 Location: Room 302, Closet (Kid's) Sill   Area (cm²): 100 Density (s/mm²): 615 Concentration (s/cm²): 592000 Asbestos Type(s): Chrysotile Tremolite   Lab No.:6501601 Client No.:3 Location: Room 302, Closet Floor (Kid's)   Area (cm²): 100 Density (s/mm²): 1690 Concentration (s/cm²): 4070000 Asbestos Type(s): Chrysotile   Please refer to the Preface of this report for further information regarding your analysis. Date Received: Date Analyzed: 4/30/2018 05/01/2018 Signature: Analyst: Craig  Liska Dated : 5/2/2018 10:09:29  Approved By: Frank E. Ehrenfeld, III Laboratory Director Page 1 of 3 9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054 Telephone: 856-231-9449 Email: customerservice@iatl.com CERTIFICATE OF ANALYSIS Report Date: Report No.: Project: Project No.: Client: Philadelphia Media Network  801 Market Street, Ste 300 Philadelphia      PA     19107 Client: PHI001 5/1/2018 562684 - TEM Dust Wipe Toxic City: Cassidy  Appendix to Analytical Report: Customer Contact: Wendy Ruderman   Analysis: ASTM D6480 - 05(2010)      This appendix seeks to promote greater understanding of any observations, exceptions, special instructions, or circumstances that the laboratory needs to communicate to the client concerning the above samples. The information below is used to help promote your ability to make the most informed decisions for you and your customers. Please note the following points of contact for any questions you may have.   iATL Customer Service: customerservice@iatl.com iATL Office Manager:  cdavis@iatl.com iATL Account Representative: Pete Lesniak Sample Login Notes:  See Batch Sheet Attached Sample Matrix: Air Cassettes Exceptions Noted: See Following Pages    General Terms, Warrants, Limits, Qualifiers: General information about iATL capabilities and client/laboratory relationships and responsibilities are spelled out in iATL policies that are listed at www.iATL.com and in our Quality Assurance Manual per ISO 17025 standard requirements. The information therein is a representation of iATL definitions and policies for turnaround times, sample submittal, collection media, blank definitions, quantification issues and limit of detection, analytical methods and procedures, sub-contracting policies, results reporting options, fees, terms, and discounts, confidentiality, sample archival and disposal, and data interpretation.    iATL warrants the test results to be of a precision normal for the type and methodology employed for each sample submitted. iATL disclaims any other warrants, expressed or implied, including warranty of fitness for a particular purpose and warranty of merchantability. iATL accepts no legal responsibility for the purpose for which the client uses test results. Any analytical work performed must be governed by our Standard Terms and Conditions. Prices, methods and detection limits may be changed without notification. Please contact your Customer Service Representative for the most current information.    This confidential report relates only to those item(s) tested and does not represent an endorsement by NIST-NVLAP, AIHA LAP LLC, or any agency of local, state or province governments nor of any agency of the U.S. government.    This report shall not be reproduced except in full, without written approval of the laboratory.    Information Pertinent to this Report: Analysis by ASTM D6480 - 05(2010)      Please see our list of international, national, state, provincial, and local certifications at www.iatl.com      TEM settled dust results are dependent upon several factors, including sampling technique. iATL can supply references that may aid in the interpretation of results.        All results are based on the samples as received at the lab. iATL assumes that appropriate sampling methods have been used and that the data upon which these results are based have been accurately supplied by the client.        Method requires submittal of blanks for analysis. Sample results are not corrected for contamination by field or analytical blanks.      Disclaimers / Qualifiers: There may be some samples in this project that have a “NOTE:” associated with a sample result. We use added disclaimers or qualifiers to inform the client about something that requires further explanation. Here is a complete list with highlighted disclaimers pertinent to this project. For a full explanation of these and other disclaimers, please inquire at  customerservice@iatl.com.    (1)Note: Sample not analyzed.   (2)Note: Sample not analyzed at request of client.   (3)Note: Sample analysis terminated. Clearance criteria exceeded (average >70.0 s/mm²). Set fails by AHERA 40 CFR 763.   (4)Note: Heavy loading (>0.1 s/cc) of non-asbestos particulate that might prohibit the required morphological, diffraction and elemental identification of asbestos. The absence of asbestos on the sample can not be concluded. Analysis for informational purposes only.   (5)Note: Heavy loading (>10% per grid opening) non-fibrous particulate. Sample analysis terminated. Clearance criteria exceeded (>10%). Sample voided by AHERA 40 CFR 763.   Dated : 5/2/2018 10:09:29  Page 2 of 3 9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054 Telephone: 856-231-9449 Email: customerservice@iatl.com CERTIFICATE OF ANALYSIS Report Date: Report No.: Project: Project No.: Client: Philadelphia Media Network  801 Market Street, Ste 300 Philadelphia      PA     19107 Client: PHI001 5/1/2018 562684 - TEM Dust Wipe Toxic City: Cassidy  (5A)Note: Heavy loading (>25% per grid opening) non-fibrous particulate. Sample analysis terminated. Clearance criteria exceeded (>25%). Sample voided by NIOSH 7402.   (6)Note: Sample turbidity >1.0 NTU. Therefore MDL >> 0.1 MFL. Does not meet National Primary Drinking Water Standards.   (7)Note: Sample integrity compromised. Received sample cassette with top open (40 CFR 763 c-e).   (8)Note: Received sample cassettes with portion of filter missing. "PCM re-prep"   (9)Note: Void - overloaded, unable to prep.   (10)Note: Void - filter damaged.   (11)Note: No volume supplied.   (12)Note: Heavy loading (>0.1 s/cc) of non-asbestos / non-fibrous particulate.   (13)Note: Method analytical sensitivity of <0.003 s/cc not attained due to volume of air sampled. NIOSH requires a minimum of 400L.   (13A)Note: Volume does not meet AHERA requirements.(<1188 L)   (14)Note: Geometric Mean = 0.xxxx Structures/cc   (15)Note: Samples received on 0.8 micron PCM filters. Samples must be submitted on 0.45 micron filter cassettes per AHERA guidelines   (18)Note: *Results are for informational purposes only. Samples received on 0.8um PCM cassettes. Per AHERA 40 CFR 763 guidelines samples must be obtained on a 0.45um cassette.               Dated : 5/2/2018 10:09:29  Page 3 of 3 9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054 Telephone: 856-231-9449 Email: customerservice@iatl.com CERTIFICATE OF ANALYSIS Client: Philadelphia Media Network  801 Market Street, Ste 300 Report Date: Report No.: Philadelphia      PA     19107 Project: Project No.: Client: PHI001 5/1/2018 562684 - TEM Dust  Wipe Toxic City: Cassidy  Rev #3, 5/2/2018  TEM WIPE SAMPLE ANALYSIS DETAILS Lab No.:6501599 Client No.:1 Volume Filtered (mL):0.1 Dilution Factor (mL):50 Grid Openings:4 Opening Area (mm²):0.013 Area Analyzed (mm²):0.0520 Sensitivity (s/mm²):19.2 Detection Limit (s/cm²):92500    Micrograph Number: EDXA Spectrum ID: Lab No.:6501600 Client No.:2 Volume Filtered (mL):0.5 Dilution Factor (mL):50 Grid Openings:3 Opening Area (mm²):0.013 Area Analyzed (mm²):0.0390 Sensitivity (s/mm²):25.6 Detection Limit (s/cm²):24700    Micrograph Number: EDXA Spectrum ID: Area Sampled (cm²):100 Location:Room 302, Top Of Air Conditioning Unit   Asbestos Structures: 4    Structures < 5 Microns: 3 Structures ≥ 5 µm: 1 Structure Density (s/mm²):  76.9 Structure Concentration (s/cm²):  370000 Asbestos Type(s): Tremolite Filter Type:MCE Filter Size (mm²):962 Pore Size (µm):0.45 Non-Asbestos Structures:None Detected    Structure Density (s/mm²):<19.2 Structure Concentration (s/cm²):<92500 Non-Asbestos Type(s): None Detected Area Sampled (cm²):100 Location:Room 302, Closet (Kid's) Sill   Filter Type:MCE Filter Size (mm²):962 Pore Size (µm):0.45 Non-Asbestos Structures:None Detected    Structure Density (s/mm²):<25.6 Structure Concentration (s/cm²):<24700 Non-Asbestos Type(s): None Detected Asbestos Structures: 24    Structures < 5 Microns: 19 Structures ≥ 5 µm: 5 Structure Density (s/mm²):  615 Structure Concentration (s/cm²):  592000 Asbestos Type(s): Chrysotile Tremolite Please refer to the Preface of this report for further information regarding your analysis. Date Received: Date Analyzed: 4/30/2018 05/01/2018 Signature: Analyst: Craig  Liska Dated : 5/2/2018 10:09:30  Approved By: Frank E. Ehrenfeld, III Laboratory Director Page 1 of 3 9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054 Telephone: 856-231-9449 Email: customerservice@iatl.com CERTIFICATE OF ANALYSIS Client: Philadelphia Media Network  801 Market Street, Ste 300 Report Date: Report No.: Philadelphia      PA     19107 Project: Project No.: Client: PHI001 5/1/2018 562684 - TEM Dust  Wipe Toxic City: Cassidy  Rev #3, 5/2/2018  TEM WIPE SAMPLE ANALYSIS DETAILS Lab No.:6501601 Client No.:3 Area Sampled (cm²):100 Location:Room 302, Closet Floor (Kid's)   Volume Filtered (mL):0.2 Dilution Factor (mL):50 Grid Openings:2 Opening Area (mm²):0.013 Area Analyzed (mm²):0.0260 Sensitivity (s/mm²):38.5 Detection Limit (s/cm²):92500    Micrograph Number: EDXA Spectrum ID: Asbestos Structures: 44    Structures < 5 Microns: 34 Structures ≥ 5 µm: 10 Structure Density (s/mm²):  1690 Structure Concentration (s/cm²):  4070000 Asbestos Type(s): Chrysotile Filter Type:MCE Filter Size (mm²):962 Pore Size (µm):0.45 Non-Asbestos Structures:None Detected    Structure Density (s/mm²):<38.5 Structure Concentration (s/cm²):<92500 Non-Asbestos Type(s): None Detected Please refer to the Preface of this report for further information regarding your analysis. Date Received: Date Analyzed: 4/30/2018 05/01/2018 Signature: Analyst: Craig  Liska Dated : 5/2/2018 10:09:30  Approved By: Frank E. Ehrenfeld, III Laboratory Director Page 2 of 3