Date 1 9/21/2017 Down 2:33 PM Resume 3:04 PM 2 9/26/2017 9:45 AM 10:44 AM Flagler Memorial Bridge Malfunction Report Response Cause PCL/Edwards adjusted Limit Switch PCL/Edwards Reseated PCL verbally told us this was a new tender who drove in wrong sequence and didn't know what to do once bridge got stuck. SW Tail lock will not drive 3 9/27/2017 10:45 AM 11:45 AM SE Tail Lock will not drive PCL/Edwards adjusted/greased so the tail lock would drive 4 12/15/2017 3:38 PM 3:58 PM Tripped Breaker PCL/Edwards swapped out breaker (SEN / SES Machinery brake breakers) to troubleshoot to see if error would repeat 5 1/3/2018 6 1/31/2018 6:15 PM 2:25 PM 7:49 PM 2:32 PM Tripped Breaker Tripped Breaker 7 2/20/2018 8 2/23/2018 4:07 PM 8:15 AM 6:43 PM 8:36 AM Brake Set timing adjustments Operator Error 2/28/2018 3/17/2018 3/25/2018 3/26/2018 3/27/2018 8:30 PM 12:15 PM 10:15 PM 10:18 AM 2:27 PM 8:40 PM 12:30 PM 2:30 AM 2:03 PM 2:33 PM Brake Set timing adjustments Traffic Gate South leaves , north span lock Torque SE Leaf/Span Lock Torque SE Leaf/Span Lock Tighten loose wires that were causing the breaker to trip ? Timing and torque adjustments were made to NE leaf to eliminate rack/pinion closing/opening face contact issue (wind-up issue). No malfunction, just extended closures while new settings were tested. (new settings worked) Emailed sent to PCL-Only experienced Tenders Timing adjustments were made on 2/28 to resolve the wind up punch list item for west leaves. Adjustments caused drives to fault. Original timing was restored on 3/1 PCL /Edwards tighten all the bolts on all traffic gates Edwards trouble shot H&H investigating and will provide a response H&H investigating and will provide a response 14 3/30/3018 8:35 PM 10:06 PM Torque SE Leaf/Span Lock PCL /HH /EHM adjusting torque back to original setting 15 3/30/2018 11:22 PM 12:44 AM Torque SE Leaf/Span Lock PCL /HH /EHM adjusting torque back to original setting 16 4/11/2018 17 4/20/2018 4:20 PM 12:45 PM 5:48 PM 1:57 PM 18 4/22/2018 19 4/27/2018 9:15 AM 4:01 PM 9:45 AM 5:10 PM NE Leaf not seating/timing out NE Leaf not seating/timing out Near Adjacent span locks would not pull Weather Event 9 10 11 12 13 Edwards Electric grease flat track and adjust closing timing from 12 sec. to 18 sec. to allow the bridge to seat properly. Adjusted torque from 15 to 20 and adjusted timing Action: Unknown bridge tender (Britney) trouble shooted and nothing was documented.