EMSL Order: 251802276 EMSL Analytical, Inc. Customer ID: MATM50 Customer PO: 3857CAC 18369 Petroleum Drive Baton Rouge, LA 70809 Tel/Fax: (225) 755-1920 / (225) 755-1989 Project ID: http://www.EMSL.com / batonrougelab@emsl.com Attention: Paul Lo MMG/Materials Management Group, Inc. Phone: (504) 368-0568 Fax: (504) 368-8409 3520 General DeGaulle Drive Received Date: 04/25/2018 9:10 AM Suite 3010 Analysis Date: 04/25/2018 Collected Date: 04/24/2018 New Orleans, LA 70114 Project: 3857CAC Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Non-Asbestos Description Appearance ROBA-11 Mastic Yellow Non-Fibrous Homogeneous 100% Non-fibrous (Other) None Detected Floor Filler Yellow/Beige Non-Fibrous Heterogeneous 100% Non-fibrous (Other) None Detected Baseboard & Glue Black Non-Fibrous Homogeneous 100% Non-fibrous (Other) None Detected Baseboard & Glue Yellow Non-Fibrous Homogeneous 100% Non-fibrous (Other) None Detected Mastic Yellow Non-Fibrous Homogeneous 100% Non-fibrous (Other) None Detected Corkboard Brown/Beige Fibrous Heterogeneous 30% Non-fibrous (Other) None Detected Corkboard Glue Yellow Non-Fibrous Homogeneous 100% Non-fibrous (Other) None Detected 251802276-0001 ROBA-12 251802276-0002 ROBA-13-Cove Base 251802276-0003 ROBA-13-Glue 251802276-0003A ROBA-14 251802276-0004 ROBA-15 251802276-0005 ROBA-16 251802276-0006 % Fibrous Asbestos Sample 70% Cellulose % Non-Fibrous % Type Analyst(s) Joshua Brunet (7) Jamie Laginess, Laboratory Operations Manager or Other Approved Signatory EMSL maintains liability limited to cost of analysis . This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by EMSL Analytical, Inc. Baton Rouge, LA NVLAP Lab Code 200375-0, LELAP 01950, TX 300238 Initial report from: 04/25/2018 16:18:19 ASB_PLM_0008_0001 - 1.78 Printed: 4/25/2018 3:18 PM Page 1 of 1