lucido & associates SERVICE ENTRANCE AND GATE PERIMETER BERM (TYP) 7' HIGH PERIMETER FENCE PERIMETER BERM / BUFFER EXISTING 4' HIGH CATTLE FENCE (TO REMAIN) 16' WIDE SERVICE PATH (TYP.) 0' 10 PERIMETER BERM WL1 EXISTING DITCH FL OW TEMPORARY PRESERVE IMPACT STABILIZED GROUND COVER (TYP.) WL6 INVERTER No. 5 MIN. FFE: 46.60 TEMPORARY PRESERVE IMPACT WAY FLOW WL5 TEMPORARY PRESERVE IMPACT TEMPORARY PRESERVE IMPACT Future Land Use: Agricultural Existing Zoning: A-2 Existing Use: Agricultural WL13B WA Y WL30 INVERTER No. 6 MIN. FFE: 46.20 16' WIDE SERVICE PATH (TYP.) WL13A INVERTER No. 8 MIN. FFE: 41.50 WL7 INVERTER No. 4 MIN. FFE: 45.30 16' WIDE SERVICE PATH (TYP.) INVERTER No. 10 MIN. FFE: 39.00 WL27 INVERTER No. 17 MIN. FFE: 43.20 INVERTER No. 12 MIN. FFE: 46.00 50' WIDE WETLAND BUFFER (TYP.) INVERTER No. 20 MIN. FFE: 42.00 STABILIZED GROUND COVER (TYP.) WETLAND CONTROL BERM STABILIZED GROUND COVER (TYP.) TEMPORARY PRESERVE IMPACT FLOW WAY WB15A WL22 WL-21 101.49' (FROM C/L) PROPOSED 15' WIDE RIGHT OF WAY EASEMENT STABILIZED GROUND COVER (TYP.) TEMPORARY PRESERVE IMPACT 50' SETBACK EXISTING OUTFALL DITCH (TO REMAIN) SOLAR COLLECTION YARD MIN. FFE: 46.50 1766.82' INVERTER No. 29 MIN. FFE: 40.04 WL16A INVERTER No. 28 MIN. FFE: 44.50 WL18 SW MORGAN STREET 97.25' EXISTING 4' HIGH WIRE FENCE 25' WIDE LANDSCAPE BUFFER 50' SETBACK Future Land Use: Rural Density Existing Zoning: A&Z Existing Use: Single Family SW MORGAN STREET 7' HIGH PERIMETER FENCE N00°02'04"W 2661.25'(M) TEMPORARY PRESERVE IMPACT WL17 TEMPORARY PRESERVE IMPACT 86.97' PRESERVE ) 88.45' INVERTER No. 35 MIN. FFE: 36.30 1'(M 768.1 "E 2 TURN AROUND TEMPORARY PRESERVE IMPACT 54'17 INVERTER No. 30 MIN. FFE: 39.20 S89°50'28"W 5262.30'(M) EXISTING 4' HIGH BARBED WIRE FENCE (TO REMAIN) 200' S13° INVERTER No. 31 MIN. FFE: 42.80 STABILIZED GROUND COVER (TYP.) AY W INVERTER No. 32 MIN. FFE: 43.50 EXISTING OVERHEAD WIRES (TYP) 86.01' EXISTING 4' HIGH BARBED WIRE FENCE (TO REMAIN) (111.45 Ac.) (12.16 Ac.) (1.80 Ac.) (0.36 Ac.) (79.84 Ac.) (11.80 Ac.) (5.50 Ac.) 11,818,578 sf. 1,969,783 sf. 184,694 sf. 5,817,549 sf. (19.7%) Project Coordinator: Gunster Law Firm 800 S.E Monterey Boulevard Stuart, FL 34996 772-288-1982 (80.3%) (271.32 Ac.) (45.22 Ac.) (4.24 Ac.) (133.55 Ac.) FPL Sweetbay Solar Energy Center Project Sign Max.: 9' Solar Panels Max.: 8' Security Fencing: - Perimeter fence shall be 7-'0" chain link. - Substation fence shall be 7'-0" chain link with 3 strands of barbed wire on extension arms to make an overall total height of 8'-0". General Notes: WL16B W EXISTING 110' WIDE FP&L OVERHEAD TRANSMISSION LINE EASEMENT INVERTER No. 33 MIN. FFE: 44.00 16' WIDE SERVICE PATH (TYP.) TEMPORARY PRESERVE IMPACT Future Land Use: Agricultural Existing Zoning: A-2 Existing Use: Agricultural PERIMETER BERM O Future Land Use: Rural Density Existing Zoning: RE-2A Existing Use: Single Family INVERTER No. 34 MIN. FFE: 37.00 FL 901.27' INVERTER No. 27 MIN. FFE: 43.60 WL23A TEMPORARY PRESERVE IMPACT 4,854,958 sf. 529,561 sf. 78,200 sf. 15,750 sf. 3,477,830 sf. 514,037 sf. 239,580 sf. Civil Engineer / Surveyor: Culpepper & Terpening 2980 S. 25th Street Fort Pierce, FL 34981 772-464-3537 Building Data: TEMPORARY PRESERVE IMPACT FLOW WAY 65' PERIMETER BERM TEMPORARY PRESERVE IMPACT Solar Array Panels: Wetland Buffer: Upland Preserve: Other Open Space: 50' WIDE WETLAND BUFFER (TYP.) 115' BORROW PIT (LAKE) AREA: 5.5 ACRES WL15 PERIMETER BERM (TYP) GATE 901.91' Future Land Use: Estate Density 2UPA Existing Zoning:RS-3 Existing Use: Single Family 230' 340' SUBSTATION FENCE Land Planner / Landscape Architect: Lucido & Associates 701 E Ocean Blvd Stuart, FL 34994 772-220-2100 24,645,562 sf. (565.78 Ac.) A-2 and AG-20A Agricultural Agriculture (Improved Pasture) Open Space /Pervious Area: 19,790,604 sf. (454.33 Ac.) INVERTER No. 26 MIN. FFE: 36.80 STABILIZED GROUND COVER (TYP.) INVERTER No. 23 MIN. FFE: 41.78 20' WIDE SERVICE PATH (TYP) Access Paths: Substation Yard: Inverter Pads: Wetlands: Troup Canal Easement: Borrow Pit / Lake: 1 50' INVERTER No. 22 MIN. FFE: 43.90 TEMPORARY PRESERVE IMPACT NG STI AY EXI W W FLO WL23B Future Land Use: Agricultural Existing Zoning: AG-20A Existing Use: Agricultural WETLAND CONTROL BERM WL25 CENTERLINE OF EXISTING ALLAPATTAH RIGHT OF WAY Total Site Area: Existing Zoning: Future Land Use Designation: Existing Use: Impervious Area: INVERTER No. 24 MIN. FFE: 39.50 Owner / Applicant: Florida Power & Light Company Site Data: WL14C 16' WIDE SERVICE PATH (TYP.) Project Team: SCALE 1"=30' TEMPORARY PRESERVE IMPACT FLOW WAY PROJECT SITE SETBACK LINE ENTRANCE DETAIL INVERTER No. 25 MIN. FFE: 34.90 WETLAND CONTROL BERM TEMPORARY PRESERVE IMPACT 1767.02' SOLAR ARRAY PANELS EXISTING FENCE PRESERVE INVERTER No. 19 MIN. FFE: 38.50 20' WIDE SERVICE PATH PROPOSED 15' WIDE RIGHT OF WAY EASEMENT PERIMETER BERM GATED SITE ENTRANCE AND PROJECT SIGN 50' 50' PROPOSED SECURITY FENCE ANAL ICT C ISTR 365) GE D AINA 21, PAGE N DR 2 TOW ER ORB DIAN P UP IN SEMENT EA (200' TEMPORARY PRESERVE IMPACT INVERTER No. 13 MIN. FFE: 45.10 INVERTER No. 21 MIN. FFE: 44.70 20' WIDE SERVICE PATH (TYP) R45' TRO INVERTER No. 14 MIN. FFE: 46.20 WL14A INVERTER No. 18 MIN. FFE: 40.00 PROPOSED GATE R45' PERIMETER BERM WL26 INVERTER No. 15 MIN. FFE: 45.40 20.1' WL14B INVERTER No. 11 MIN. FFE: 46.30 Key / Location: PROPOSED SIGN (MAX. 9' HIGH) TEMPORARY PRESERVE IMPACT INVERTER No. 16 MIN. FFE: 44.00 WL29 EXISTING EDGE OF PAVEMENT L1 (100' WIDE RIGHT OF WAY) 0' 10 FLOW WAY N00°07'56"E 2017.24'(M) TURN AROUND 103.99' (FROM C/L) SW ALLAPATTAH ROAD (COUNTY ROAD 609) INVERTER No. 9 MIN. FFE: 34.60 NA CA CT 5) RI S T E 36 DI G GE , PA 1 NA AI B 22 DR N R OR W TO T PE AN DI MEN IN SE P OU ' EA TR 200 ( STABILIZED GROUND COVER (TYP.) WL12 WETLAND CONTROL BERM M) 9'( INVERTER No. 7 MIN. FFE: 40.60 TEMPORARY PRESERVE IMPACT STABILIZED GROUND COVER (TYP.) 8.9 AY INVERTER No. 2 MIN. FFE: 46.30 INVERTER No. 3 MIN. FFE: 44.50 FLOW WAY SEE 102.1' (FROM C/L) ENTRANCE DETAIL WW 6 23 Future Land Use: Agricultural Existing Zoning: AG-20A Existing Use: Agricultural FLO TEMPORARY PRESERVE IMPACT FLOW W AY PRESERVE IMPACT "E 7' HIGH PERIMETER FENCE WL10A WL11 8 5'1 INVERTER No. 1 MIN. FFE: 46.40 WETLAND CONTROL BERM (TYP) TEMPORARY °2 TEMPORARY PRESERVE IMPACT FLOW WAY TURN AROUND 50' SETBACK 3 S3 100.6' (FROM C/L) WL10B S89°57'53"E 4055.00'(M) (772) 220-2100, Fax (772) 223-0220 SOLAR ARRAY PANELS (100' WIDE RIGHT OF WAY) Future Land Use: Agricultural Existing Zoning: AG-20A Existing Use: Agricultural SW ALLAPATTAH ROAD (COUNTY ROAD 609) 701 SE Ocean Blvd., Stuart, Florida 34994 N89°47'10"W 765.81'(M) EXISTING OUTFALL (TO REMAIN) Future Land Use: Rural Density Existing Zoning: RE-2A Existing Use: Single Family - During construction activities, existing native vegetation shall be retained to act as buffers between adjacent land uses, and to minimize nuisance dust and noise. Barricades shall be used on site to preserve the vegetation to be retained. - Proposed lakes within 200' of wetlands must demonstrate no potential wetland impacts. - All exotic plant species shall be removed and all required landscaping shall be installed prior to December 31, 2020 - Refer to landscape plans for landscape details and specifications. - Preserve areas may not be altered except in compliance with the preserve area management plan approved by Martin County. - Wetland Buffer preserve areas and upland preserves shall be protected from encroachment, construction and other activities by providing a minimum 10' setback from all proposed structures. Excavation and fill activities must maintain a minimum five (5) feet setback from preserve areas. The maximum slope of fill adjacent to the setback shall not exceed one (1) foot vertical to four (4) feet horizontal. - Preserve signs will be at least 11 x 14 inches in size and will be posted in conspicuous locations along the Preserve Area boundary, at a frequency of no less than one (1) sign per 500 feet. - Refer to PAMP for Temporary Preserve Area Impact Restoration Plans and Preserve Sign locations and detail. - Graded areas adjacent to preserve areas shall not exceed a slope of one foot vertical to four feet horizontal. All slopes shall be properly stabilized upon completion of construction to the satisfaction of the County Administrator. - It shall be unlawful to alter the approved slopes, contours, or cross sections or to chemically mechanically, or manually remove, damage, or destroy any plants in the littoral or upland transition zone buffer areas of constructed lakes except upon the written approval of the Growth Management Director, as applicable. It is the responsibility of the owner or property owners association, its successors or assigns to maintain the required survivorship and coverage of the reclaimed upland and planted littoral and upland transition areas and to ensure ongoing removal of prohibited and invasive non-native plant species from these areas. - Irrigation Source: Water Truck Indiantown/ Martin County, Florida Final Site Plan Date 06.21.2018 10.04.2018 11.13.2018 LEGEND By Description S.L.S. S.L.S. S.L.S. Initial Submittal 1st Resubmittal 2nd Resubmittal NORTH WETLAND PRESERVE - 79.84 ac SCALE: 1" = 300' WETLAND BUFFER - 45.22 ac UPLAND PRESERVE - 4.24 ac TEMPORARY PRESERVE IMPACT AREA SOLAR ARRAY PANELS DRAINAGE FLOW WAY 0 150' 300' 600' REG. # 1018 Thomas P. Lucido Designer --- Sheet Manager --- Project Number --- Municipal Number --- 1 of 1 Computer File 17-626 FPL Sweetbay Solar.dwg STABILIZED GROUND COVER C