Real East Texas CITYOFLONGVIEW (g February 28, 2019 9171 9690 0935 0192 2165 38 Mr. Bhupendra Patel, IN REM Ma Krupa LLC 3120 Estes Pkwy Longview, TX 75602 Our records indicate that you are the owner or person in control of the property at 3120 Estes Pkwy, Longview, TX. On February 27, 2019 city of?cials from the Building, Code Compliance and Fire department, performed a walk-thru inSpection of this property and identi?ed several major and minor violations of the City of Longview Code of Ordinances. As a result of the severity of the infractions you are recommended to hire a structural and electrical engineer in order to rectify the problems. In order to correct the violations and avoid any further actions, submit to the City of Longview Building Of?cial your detailed plan specifying the corrective measures that will be taken. This plan is due within 7 days of receipt of this letter. Prior to beginning any work you will be required to pull the necessary permits from the City of Longview's Development Services Department and you will have to obtain a Certi?cate of Occupancy. If you have any questions you may call me at (903)237-1363. Sabrina Graves Environmental Compliance Inspector Real East Texas CITYOFLONGVIEW February 27, 2019 EXPRESS INN The major concerns are the structural and electrical deficiencies Need structural engineer to evaluate all failing structures such as stairwells, landings, elevated walk ways, guard rails, roof supports, columns, and foundation supporting these. Submit detail plans for repair/replace Need electrical engineer to evaluate the main distribution panel in the pool storage room clue to the fact the entire main distribution panel is rusted and approximately 3 to 4 inches of metal has deteriorated/corrode off the bottom. STRUCTURAL SUPPORT of some we identifv. not all of them The main building has loose support columns on north side and east side of structure Columns separated on one end and crack on the other end by room it 247 Corner post columns with cracks] breaks at top of column room #238,239,240,242,243,226,225, 224,223, 8: 222 Support columns with cracks and breaks at bottom or top and not secured, room thru 101, 102, 103, 105, 104,247,238,110 and multiple columns on floor of main bldg. on the south side First level by room it 223 Above room ll 122 Rotted wood around the corner of roomll 319 8: room it 3 top floor Railing by room fl 321 very loose around the corner side Railing by room 324-323 Room #221 only thing holding together is 2 4 2nd floor very loose Stairs unsafe by room ll 228 Real East Texas CITYOFLONGVIEW Violations Exit lights not working properly (lobby) Exits doors need to be unlocked at all times if building is occupied by renters] need exits sign at all exit doors Corrosion on ?re alarm control panel wires (behind front desk) Hole in wall next to coffee maker (lobby area) Boiler room -Need C02 detector, need 3ft clearance, remove cabinet and other miscellaneous items, blanks missing in breaker panel, all holes need to be caulked and repaired Banquet room- removed all miscellaneous items for clearance, need ?re extinguisher Leak needs to be repaired (front entry in banquet room) Fan not working in ladies bathroom-(lobby) Fan, light, toilet not working men's bathroom (lobby) Fire extinguisher between room ll 225 224 is on the recall list All non-working light fixtures need to be repaired Hose bib leaking by room it 229 All room numbers need to be identified correctly Door at unit #236 needs to be repaired Broken window at #245 Pot holes in parking lot/ re stripe parking lot (fire lane) Real East Texas Building it 3124 bar area Air conditioner at rear-cover needs to be repaired Rotten wood on fascia at front of structure Leaking roof at front of structure Gutter an east side of structure need to be repaired [replaced South east corner of building rotted wood